Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 352
Filtrar
1.
J Conserv Dent Endod ; 27(3): 262-267, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38634037

RESUMO

Context: Safe and efficient removal of all root filling materials from the root canal system without compromising radicular dentin structure is essential for optimal nonsurgical retreatment. Aims: The aim of this study was to evaluate and compare the incidence of dentinal defects caused during root canal filling removal using conventional, rotary, and reciprocating retreatment file systems. Settings and Design: A detailed protocol explaining purpose and procedures of the study was submitted to the Institutional Ethics Committee and ethical clearance obtained. Subjects and Methods: Sixty human maxillary permanent central incisors were collected and decoronated to 12-mm standardized length. The canals prepared up to a master apical file size F3 with Protaper hand files, obturated using AH plus sealer, examined under the stereomicroscope (×40 magnification): Group I: Control (n = 15), Group II: Conventional (n = 15), Group III: Protaper Universal Retreatment Files (n = 15), and Group IV: Reciproc Blue (n = 15). After instrumentation, teeth were sectioned at 3, 6, and 9 mm from the apex to evaluate the presence of dentinal defects under the stereomicroscope. Statistical Analysis Used: Statistics were performed using the SPSS, version, 25 (SPSS Inc., Chicago, IL, USA). Initially, normality test was done using the Shapiro-Wilk test and data were not normally distributed followed by Kruskal-Wallis test. P < 0.05 is considered statistically significant. Results: Maximum percentage increase in dentinal defects was observed in Protaper Universal Retreatment Files followed by Conventional method and Reciproc Blue. Conclusions: Significantly Reciproc Blue reduced the incidence of dentinal defects after root canal preparation.

2.
Cureus ; 16(3): e56466, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38638716

RESUMO

BACKGROUND: Despite substantial breakthroughs in instrumentation systems and pharmaceutical interventions, pain following endodontic therapy remains a serious concern. The effect of the type of endodontic instrumentation system in post-operative pain after endodontic therapy has been a matter of debate. AIM: To evaluate different endodontic instrumentation systems, namely Reciproc (GmbH, Munich), OneShape® (MicroMega, France), Protaper Gold (Dentsply Sirona, USA), and Hyflex® EDM (Coltène/Whaledent Inc., USA) file systems, regarding post-operative pain after endodontic therapy Methods and materials: The endodontic department treated healthy patients aged 20 to 50 years who were experiencing symptoms of irreparable pulpitis in one or more maxillary molars or mandibular molars. Five hundred was the determined size of the sample. The study participants were divided into five categories, each comprising 100 participants. These categories were: Category 1: Reciproc instrumentation system. Category 2: OneShape® instrumentation system. Category 3: ProtaperGold instrumentation system. Category 4: HyFlex® EDM instrumentation system. Category 5: Control (stainless steel K-files). Following endodontic therapy, these scores were recorded at 6 hours, 12 hours, 24 hours, 48 hours, and 72 hours using the VAS scale. RESULTS: The visual analog scale (VAS) score (mean±SD) in the control group was 0.73± 0.40 (<0.001). The VAS score in the Reciproc group was 0.43± 0.05 (<0.001). The VAS score in the OneShape® group was 0.36±0.09 (<0.001). The VAS score in the Protaper Gold group was 0.41 ±0.08 (<0.001). The VAS score in the HyFlex® EDM group was 0.55 ±0.02 (<0.001). The VAS score in all instrumentation techniques at 72 hours follow-up was lesser in comparison to a control group with meaningful statistical significance (<0.001). However, the post-operative pain among the Reciproc, OneShape®, Protaper Gold, and HyFlex® EDM instrumentation systems was not different clinically when compared among themselves. However, VAS values were greater in OneShape® and HyFlex® EDM compared to Reciproc and Protaper Gold, showing increased post-operative pain in OneShape and HyFlex® EDM compared to Reciproc and Protaper Gold. It was also observed that there was a decline in the VAS score in all instrumentation systems as the follow-up period increased from 6 hours to 72 hours, with maximum post-operative pain at 6 hours of follow-up and minimum post-operative pain at 72 hours of follow-up. However, the decline was lesser in OneShape® and HyFlex® EDM in comparison to Reciproc and Protaper Gold, with increased post-operative pain in OneShape® and HyFlex® EDM in comparison to Reciproc and Protaper Gold. CONCLUSION: Post-operative pain at all follow-ups of endodontic procedures was less in Reciproc, OneShape®, Protaper Gold, and HyFlex® EDM than in the control group. VAS scores were higher in the OneShape® and HyFlex® EDM groups compared to the Reciproc and Protaper Gold groups, indicating increased post-operative pain with OneShape® and HyFlex® EDM instruments in comparison to Reciproc and Protaper Gold.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38461490

RESUMO

PURPOSE: Pulpectomy can be used for the management of deep dentinal carious lesions in primary teeth which can be restored. Mechanical preparation of root canals can be performed using hand or NiTi rotary files. However, this may cause dentinal stress and consequently dentinal microcracks. Hence, the aim was comparative evaluation of hand and rotary file systems on dentinal microcrack formation during pulpectomy procedure in primary teeth. METHODS: 60 extracted primary molar teeth were selected comprising of 80 root canals. Simple random sampling was used to divide root canals into four groups (n = 20): Group A-Hedstrom file, Group B-Pro AF Baby Gold rotary, Group C-ProTaper Next rotary, and Group D-unprepared group. Assessment was conducted on presence or absence of microcracks using Chi square test (p < 0.05). RESULTS: The total number of microcracks in Group A: one (5%), Group B: four (20%), Group C: nine (45%) and Group D: zero (0%) which was statistically significant (p = 0.002). At cervical third, the number of microcracks seen with Group A: one (5%), Group B: zero (0%), Group C: five (25%) and Group D: zero (0%) (p = 0.005). At the middle third, the number of microcracks seen in Group A: zero (0%), Group B: four (20%), Group C: four (20%) and Group D: zero (0%) (p = 0.029). CONCLUSION: The study concluded that dentinal microcracks are formed with both hand and rotary file systems in primary teeth. ProTaper Next showed significantly higher number of microcracks, followed by ProAF Baby Gold and H files.

4.
Cureus ; 16(2): e54310, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38496119

RESUMO

Background Successful endodontic treatment relies on the effective removal of debris and the prevention of smear layer formation within the root canals. The choice of nickel-titanium (Ni-Ti) rotary instrument systems can significantly impact these outcomes. Aim This study aims to evaluate and compare the debris and smear layer formation in root canals of extracted mandibular second premolar teeth following instrumentation with the ProTaper Universal (Dentsply Sirona, Charlotte, NC) (Group II), Twisted File (Kerr Endodontics, Gilbert, AZ) (Group III), and XP Endo (FKG Dentaire, La Chaux-de-Fonds, Switzerland) (Group IV) Ni-Ti rotary instrument systems. Methods In this in vitro study, 60 extracted mandibular second premolar teeth were randomly divided into four groups, each containing 15 teeth. Group I served as the control with no instrumentation. Groups II, III, and IV were instrumented with the ProTaper Universal rotary file, the Twisted File, and the XP Endo file systems, respectively. Debris and smear layer formation were evaluated through scanning electron microscopy (SEM), and photomicrographs were scored using a standardized index. Results Group II (ProTaper) exhibited the highest mean debris and smear layer scores, with values of 3.50 and 2.70, respectively. Group IV (XP Endo) demonstrated the least debris and smear layer formation, with mean scores of 2.65 and 2.08, respectively. Statistical analysis confirmed significant differences among the groups for both debris and smear layer formation. Conclusion The results highlight the practical importance of selecting appropriate Ni-Ti rotary instrument systems to minimize debris and smear layer formation during endodontic procedures. The XP Endo file system showed promise as a favorable choice in this regard, but further clinical research is needed to validate these findings.

5.
Cureus ; 16(2): e53506, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38440012

RESUMO

INTRODUCTION: Biomechanical preparation has gotten easier over time with the development of nickel-titanium (NiTi) rotary instruments. Despite their benefits, research has shown that these files frequently result in microcracks in the root canal dentin, which can fracture the roots. Such mishaps should be prevented, as they compromise the integrity of the root and reduce the long-term survival of endodontically treated teeth. MATERIALS AND METHODS: This study was conducted at Government Dental College and Hospital, Patiala, Punjab, India. Eighty permanent mandibular premolar teeth were included. All the roots were inspected for any pre-existing cracks or craze lines under a stereomicroscope. The teeth were decoronated and then divided into four groups (n = 20): Group I: TruNatomy, Group II: Neoendo Flex, Group III: ProTaper Gold, and Group IV: 2Shape. The samples were instrumented according to the group to which they belonged. The roots were then sectioned horizontally at 3 mm and 6 mm from the apex and examined under a stereomicroscope at 40x for the presence of microcracks. RESULTS: The data were analyzed using the IBM SPSS Statistics for Windows, version 26 (released 2019; IBM Corp., Armonk, New York, United States). A chi-square test was applied, and the level of significance was set at p < 0.05. The highest incidence of microcracks was associated with ProTaper Gold (65%), followed by Neoendo Flex (45%), TruNatomy (20%), and 2Shape (20%). CONCLUSION:  All rotary instruments resulted in dentinal damage. ProTaper Gold exhibited the highest frequency of dentin cracks. TruNatomy and 2Shape exhibited satisfactory results with minimal crack formation.

6.
J Contemp Dent Pract ; 24(9): 715-721, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38152947

RESUMO

AIM: This research was carried out with the objective of comparison between GenEndo, Protaper Gold, Hero Gold and EdgeFile X3 regarding the effect of different concentrations of NaOCl. MATERIALS AND METHODS: About 720 study specimens were included in the study. They were divided into four groups. Each group consisted of 180 files. Group A: GenEndo, Group B: Protaper Gold, Group C: Hero Gold, Group D: EdgeFile X3. Each group of instruments were further subdivided into nine subgroups (n = 20 for each subgroup). Testing of the cyclic fatigue was carried out in artificial canals which were prepared inside the blocks of stainless steel. The stainless steel blocks with artificial canals were established in a receiver that was packed with experimental solutions like distilled water, 5.25% NaOCl and 2.5% NaOCl. The adjustment of temperature was done at 25, 37, and 60°C. The rotation of the instrument was carried out inside the artificial canal as per the instructions of the manufacturer. The instrument was rotated until it got fractured. The time taken by the instrument to fracture was recorded in seconds. The number of cycles to fracture (NCF) was analyzed with the help of the equation (NCF = time to fracture × rpm/60). Surfaces at the site of fracture were examined with the help of a scanning electron microscope (EVOLS10, ZEISS) at magnification (300x and 2000x). RESULTS: It was noticed that there was a statistically significant increase in cyclic fatigue when sodium chloride was used as an endodontic irrigant instead of distilled water. The increase in cyclic fatigue was also observed when 5.25% sodium chloride was used instead of 2.5% sodium hypochlorite. Cyclic fatigue increased on change in temperature from 25 to 37°C and from 37 to 60°C. The difference was statistically significant (p < 0.05). It was observed that resistance against cyclic fatigue on treatment with different irrigation solutions at different temperatures was in the order of GenEndo > Protaper Gold > Hero Gold > EdgeFile X3. CONCLUSION: The resistance against cyclic fatigue in new NiTi rotary files can be affected significantly by different concentrations of sodium hypochlorite irrigant solution and the GenEndo rotary endodontic instrument has the maximum resistance against cyclic fatigue. CLINICAL SIGNIFICANCE: Irrigation of the root canal with irrigants, such as sodium hypochlorite (NaOCl) has been recommended strongly. NaOCl is used in the range of 0.5 and 6.5% concentration owing to its antimicrobial activity and tissue dissolution activities, particularly at higher temperatures. It has been postulated that fatigue of rotary endodontic instruments can be influenced by adjoining medium and their concentration.


Assuntos
Instrumentos Odontológicos , Falha de Equipamento , Teste de Materiais , Preparo de Canal Radicular , Cloreto de Sódio , Hipoclorito de Sódio , Aço Inoxidável , Temperatura , Titânio , Água
7.
BMC Oral Health ; 23(1): 902, 2023 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-37990209

RESUMO

OBJECTIVES: To evaluate the amount of remaining filing material and apical debris extrusion after retreatment using Reciproc Blue, Hyflex EDM and ProTaper Retreatment Files. MATERIALS AND METHODS: Thirty-six extracted permanent mandibular first molars with moderately curved mesial roots were selected. Mesiobuccal canals were prepared using the ProTaper Next system up to size X2 and filled using gutta-percha and Adseal sealer via cold lateral compaction. Teeth were randomly divided into three equal groups (n = 12): Group 1: Reciproc Blue (RB)(VDW, Germany), Group 2: Hyflex EDM (HEDM)(Coltene/Whaledent, Switzerland), Group 3: ProTaper Universal Retreatment file system + ProTaper Next file system (PTUR + PTN)( Dentsply Maillefer, Switzerland). Eppendorf tubes were used to collect the apically extruded debris. Cone-beam computed tomographic scans were taken prior to and after retreatment and the volume of remaining filling material was assessed at the coronal, middle and apical levels. Statistical analysis was performed using the Kruskal-Wallis test, Friedman's test and Wilcoxon Sign Rank test. Significance level was set at p value 0.05. RESULTS: There were no statistically significant differences among the three groups in the reduction of the volume of the filling material or in the amount of apically extruded debris. CONCLUSION: All the tested filing systems showed similar efficacy in removing the filling material, however, none of them could achieve its complete removal. Apical extrusion of debris occurred with all the systems used with no significant difference between the three groups.


Assuntos
Materiais Restauradores do Canal Radicular , Dente , Humanos , Preparo de Canal Radicular/métodos , Obturação do Canal Radicular/métodos , Guta-Percha , Cavidade Pulpar/cirurgia , Retratamento
8.
J Pharm Bioallied Sci ; 15(Suppl 1): S442-S446, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37654264

RESUMO

Aim: The aim of the present study was to comparatively assess the cleansing efficiency of dissimilar rotary files in deciduous teeth. Materials and Methods: Forty-five deciduous anterior teeth that had been subjected to extraction were chosen for this research. The teeth were included if they had a minimum of 2/3rd undamaged root portions. Coronal entrée was completed using round diamond burs. All 45 samples were allocated at random to one of the following three groups: Group I: Control group in which the radicular canal was not subjected to any form of instrumentation, Group II: The radicular canal was subjected to instrumentation employing rotary ProTaper files, Group III: The radicular canal was subjected to instrumentation with rotary MTwo files. The samples were subjected to immersion in a succession of diluted ethyl alcohols to permit dehydration: With a change of solution every eight hours, the first 16 hours were spent in 70% alcohol, followed by eight hours in 80% alcohol, eight hours in 95% alcohol, and eight hours in 100% alcohol. The samples thus subjected to dehydration were cleared by immersion in methyl salicylate for six hours. Under a stereomicroscope with a 10x magnification, the root canals were examined by a person who was blinded to the groups in order to look for any traces of ink in the coronal, middle, and apical third of the canals. Results: In the control group, greater residual remains were present in the apical 3rd at 2.16 ± 0.08 followed by the coronal 3rd at 2.02 ± 0.14, and then in the middle 3rd at 1.88 ± 0.10. While using the ProTaper files, greater residual remains were present in the middle portion at 1.68 ± 0.16, followed by the coronal third at 0.94 ± 0.09, then the apical third at 0.98 ± 0.22. Greater residual remains were again noted with the MTwo files in the mid-portion at 1.44 ± 0.18, followed by the coronal part at 0.86 ± 0.10 and then the apical part at 0.82 ± 0.04. Differences among these groups were statistically significant with a P value < 0.001. Conclusion: The present study concluded that either of the file types used exhibited reasonably lower remnant score values in the apical third versus the middle/coronal thirds. Nonetheless, MTwo type files delineated superior capacity at removing debris versus the ProTaper file types at the apical level.

9.
J Pharm Bioallied Sci ; 15(Suppl 1): S434-S437, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37654422

RESUMO

Aim: The aim of this research was to assess the damage to root dentin that arises from retreatment with different engine-driven NiTi retreatment files employing micro-computed tomography. Materials and Methods: Sixty mandibular premolar teeth having a single root and root canal that were recently extracted were gathered and stored. The specimens were de-coronated at the cementoenamel junction under water irrigation to achieve a homogeneous root length of 16 millimeters. Gutta-percha cones were coated with sealants and placed within the radicular canal till the WL. All sixty premolars were randomly assigned to one of the following three groups, with every group comprising 20 sample teeth each. Group 1: MTwo Retreatment files, Group 2: ProTaper Universal Retreatment files, Group 3: Edge File XR Retreatment rotary files. The quantity of root dentinal injury was estimated by deducting the dentin volume (mm3) in the pre- and post-therapy micro-CT scans at apical, middle, and cervical 3rd points. Results: An intra-group comparative scrutiny showed that lower radicular dentinal injury was noted at apical 3rd (0.31 ± 0.16, 0.62 ± 0.02) in Edge File XR Retreatment file system and MTwo Retreatment file system in that order. The statistically significant disparity was seen amid the MTwo Retreatment file, Edge File XR Retreatment file system and ProTaper Universal Retreatment file, Edge File XR Retreatment file system with P value of 0.001on intergroup assessment. Conclusion: In spite of the limitations that this research had, it was inferred that each assessed file system proficiently eradicated the obturated material through the retreatment procedure performed. In addition, it was seen that the Edge File XR group showed lesser root dentin damage in contrast to MTwo and ProTaper Universal file systems.

10.
J Endod ; 49(12): 1733-1738, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37717909

RESUMO

INTRODUCTION: Innovative file systems have been recently introduced, claiming improved effectiveness and superior ability to preserve the tooth structure, still allowing an efficient preparation and disinfection up to the apical region. Regardless, few data are available on the comparative effectiveness of the most recently developed systems. Thus, this ex vivo study aimed to comparatively evaluate, for the first time, the functionality of WaveOne Gold (WOG), TruNatomy (TN), and ProTaper Ultimate (PU) file systems regarding canal shaping, dentin preservation, and smear layer removal ability. METHODS: Human maxillary incisors were randomly divided for instrumentation with one of the assayed systems. Canal shaping ability and pericervical dentin preservation were characterized through microtomographic evaluation and morphometric assessment (n = 15). Smear layer removal ability was evaluated by scanning electron microscopy (SEM) (n = 6). RESULTS: TN and PU presented the lowest canal volume variation upon instrumentation, found to be significantly lower than that attained with WOG (P < .05). Pericervical dentin was reduced in all groups upon instrumentation, with TN evidencing the highest preservation, quantitatively similar to PU, and significantly higher than that attained with WOG (P < .05). SEM imaging revealed the presence of scattered remnants of the smear layer and partially opened dentinal tubules at the apical portion, with no significant differences between systems. CONCLUSIONS: TN and PU allowed for the highest tissue preservation, reporting the lowest volume variation and the highest preservation of the pericervical dentin. None of the assessed systems provided a complete removal of the smear layer in the apical region.


Assuntos
Camada de Esfregaço , Humanos , Dentina , Cavidade Pulpar/diagnóstico por imagem , Ouro , Preparo de Canal Radicular , Irrigantes do Canal Radicular
11.
J Conserv Dent Endod ; 26(4): 472-477, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37705559

RESUMO

Aim: The aim of this study was to assess and compare the influence of the presence of full-coverage crown on the obturation material removal efficiency of different retreatment file systems. Materials and Methods: Sixty extracted, human, maxillary premolars were accessed, instrumented, and obturated with gutta-percha and AH Plus sealer. The samples were scanned with cone-beam computed tomography and volume of obturating material was measured using ITK-SNAP volumetric software. Samples were divided (n = 30) into with and without all metal full-coverage crown groups. Each group was then subdivided into three subgroups (n = 10) based on retreatment file used (ProTaper URS, HyFlex Remover, and NeoEndo). The volume of remnants of obturating material was remeasured by image segmentation using ITK-SNAP volumetric software. One-way analysis of variance, followed by the Tukey's post hoc test, was used for data analysis, with a significance level of 5%. Results: A significant difference in percentage remnant of obturating material after retreatment file was observed on overall comparison between with (29.84%) and without crown (21.79%) groups (P < 0.05). Each file system removed significantly more obturating material in without crown samples than with crown samples (P < 0.05). The percentage remnant of obturating material after retreatment file use was as follows: ProTaper URS > NeoEndo retreatment file > HyFlex Remover. All file systems showed significantly different (P < 0.05) efficiency in removal of obturating material. Conclusions: None of the retreatment file systems were able to remove obturating material completely. The presence of full-coverage crown negatively impacted the efficiency of retreatment files for the removal of obturating material. HyFlex Remover performed better than NeoEndo which was better than ProTaper URS.

12.
J Conserv Dent Endod ; 26(4): 420-423, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37705551

RESUMO

Background: Cleaning and shaping represent a vital step in the endodontic procedure. In routine endodontic therapy, the fracture of nickel-titanium (NiTi) instruments is a procedural problem creating a major obstacle to therapy. Aim: This study examines the life span of one Neoendo Flex and ProTaper Next (PTN) rotary file using reciprocating motion and compares the time required by both file systems for canal preparation. Materials and Methods: One hundred maxillary permanent central incisors were selected. In that, fifty teeth are utilized in a reciprocating motion (RM) with the PTN file (n = 25) and Neoendo Flex file (n = 25). To check fractured resistance and the overall root canal preparation time, fifty more teeth are employed in continuous motion (CM) with canals prepared using PTN (n = 25) and Neoendo Flex (n = 25). All canals are prepared following the sequence of respective files. Later, the fracture mechanism of the files was inspected using a scanning electron microscope. Results: In an RM motion, both PTN and Neoendo Flex files can be used in a minimum of 25 canals in single-rooted teeth. Statistical analysis using the Mann-Whitney U-test showed no significant difference in total time taken by PTN and Neoendo Flex in both motions. Conclusion: Within the limitation of this study, the RM was found to be better than CM with less incidence of instrument fracture.

13.
J Pharm Bioallied Sci ; 15(Suppl 2): S1072-S1074, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37693987

RESUMO

Background and Objectives: The aim of this study was to see the incidence of cracks in root dentin after coronal flaring using various rotary instruments such as Gates Glidden (GG) drills, ProTaper Universal SX, OneFlare, and HyFlex EDM. Materials and Methods: Seventy freshly extracted premolar teeth with single canal were collected. All the teeth were randomly divided into five groups of fourteen each (n = 14), of which one group served as the control and the rest of the four groups were instrumented with GG drills, ProTaper Universal SX, OneFlare, and HyFlex EDM, respectively. Results: The GG drills resulted in a higher rate of crack formation in root dentin (P < 0.05) than the ProTaper Universal SX, OneFlare, and HyFlex EDM instruments (P > 0.05). Conclusion: The use of GG drills resulted in more crack formation. However, the results for the ProTaper Universal SX, OneFlare, and HyFlex EDM flaring instruments were less in terms of crack formation.

14.
Dent Med Probl ; 60(3): 421-426, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37750735

RESUMO

BACKGROUND: The extrusion of apical debris is related to various factors, and may be affected by variations in technique or instrumentation system. Although the extrusion cannot be completely prevented, it is crucial to minimize the amount of extruded material. OBJECTIVES: The present study aimed to compare apical debris extrusion by the novel TruNatomy (TRN), OneCurve (OC) and ProTaper Next (PTN) instruments in curved root canals. MATERIAL AND METHODS: A total of 60 multi-rooted human mandibular molar teeth with moderate and severe curvature were selected and randomly divided into 3 groups. The root canals were prepared with the OC, TRN and PTN files. For collecting the debris extruded through the apical foramen, Eppendorf tubes were used. After the vaporizing period, the tubes were re-weighed, and the amount of the extruded debris was calculated by subtracting the initial weight from the final weight. Statistical analysis was performed with the Shapiro-Wilk and Kruskal-Wallis tests. The statistical significance level was set at p < 0.05. RESULTS: The least amount of debris was extruded with TRN and the greatest with PTN, but the difference between the groups was not significant (p = 0.257). CONCLUSIONS: All instrumentation systems were associated with debris extrusion. The tested file systems presented similar results in terms of apical debris extrusion in curved canals. The novel TRN system demonstrated promising results, comparable to OC and PTN.


Assuntos
Preparo de Canal Radicular , Ápice Dentário , Humanos , Ápice Dentário/cirurgia , Dente Molar/cirurgia
15.
PeerJ ; 11: e15830, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37576504

RESUMO

Background: This study compared the ability of thermally treated files in shaping simulated canals with double curvature. Fifty-six canals were enlarged to a final size of 25 with ProTaper Next (PTN) or ZenFlex (ZF). Materials: Half of the samples were shaped with cooled files (n = 14 each). The amount of removed resin was measured and canal deviation was determined at eight levels. Shaping time and maximum shaping torque values were also recorded. Data were statistically analyzed using analysis of variance and LSD, Kruskal-Wallis, and chi-square tests at a 0.05 significance level. Results: Compared to PTN and cooled PTN, ZF and cooled ZF required lesser time to shape the canals. The maximum torques were found comparable between the groups. All the groups generated negligible deviations at every canal level evaluated and maintained the canal geometry. Although not significant, the cooled PTN and ZF files exhibited lesser canal deviations than their counterparts. Conclusion: All groups demonstrated similar shaping ability whilst maintaining the original curvature of the canal in simulated canals with double curvature. However, ZF groups were able to shape the canals faster than PTN groups. There was a trend that cooled files made lesser canal deviations compared to their counterparts.


Assuntos
Temperatura Baixa , Equipamentos Odontológicos , Preparo de Canal Radicular , Desenho de Equipamento , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Preparo de Canal Radicular/normas , Torque , Análise de Variância , Equipamentos Odontológicos/normas
16.
J Conserv Dent ; 26(3): 288-291, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37398865

RESUMO

Aim: The aim of this study was to assess and compare the quantity of apically debris which was extruded apically by TruNatomy (TN), ProTaper Next (PTN), HyFlex electric discharge machining (EDM), and HyFlex controlled memory (CM), following root canal preparation. Materials and Methods: Sixty extracted single-canal mandibular premolars were used. The root canal preparation was done with TN, HyFlex EDM, PTN, or HyFlex CM files. The preweight debris, which was extruded apically, was collected in the Eppendorf tube and later on incubated at 670°C for 3 days and weighed again to record the extruded debris. Results: The result showed that there was a significant reduction in debris extrusion by TN system, followed by PTN system, HyFlex EDM, and maximum extrusion in HyFlex CM (P < 0.05). Between the PTN and TN groups as well as between the HyFlex EDM and HyFlex CM groups, statistically significant difference was not observed (P > 0.05). Conclusion: Apical debris extrusion is the inherent nature of the all file systems. Nevertheless, the TN file system produced substantially minimum debris extrusion among other systems compared in the study.

17.
Cureus ; 15(6): e40904, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37492825

RESUMO

Aim The aim of this study was to compare the amount of debris produced apically during the removal of root canal obturating material by using various files in extracted teeth with simulated apical root resorption. Materials and methods An in vitro study was conducted in the root canals of 90 extracted mandibular premolar teeth that were prepared with a ProTaper Gold rotary file (Dentsply Maillefer, Ballaigues, Switzerland) and filled with gutta-percha and an AH Plus sealer (Dentsply Maillefer, Ballaigues, Switzerland) using a cold lateral compaction technique. A total of 45 mandibular premolar teeth were randomly assigned to three control groups (i.e., the ProTaper Universal retreatment file (Dentsply Maillefer), the Reciproc Blue file (VDW, Munich, Germany), and the HyFlex Remover file (Coltene/Whaledent, Altstatten, Switzerland) for the removal of root canal filling material, whereas the remaining 45 teeth were treated as the experimental group and their apical portion was modified to simulate apical root resorption. The teeth of this experimental group were randomly divided into three subgroups according to the same three techniques used with the control groups for the removal of root canal filling materials. The apically extruded debris was collected into pre-weighed borosilicate glass tubes and then dried. The mean weight of the apically extruded debris was assessed using an analytical balance to an accuracy of 10-4 g. Further, the data were analyzed using the Kruskal-Wallis test and Tukey's post hoc test. Results In the simulated apical root resorption groups, all file systems were associated with significantly more debris extrusion than the groups without simulated root resorption (a < 0.05). In both the control groups and experimental groups, the ProTaper Universal retreatment file was associated with the least weight of the apically extruded debris (a < 0.05), followed by the Reciproc Blue file and the HyFlex Remover file. Conclusion The amount of debris extruded apically was significantly greater in the teeth with simulated apical root resorption than in those without it. Further, during the removal of the root canal filling materials, HyFlex Remover was associated with significantly more apically extruded debris in all groups.

18.
Indian J Dent Res ; 34(1): 65-68, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37417060

RESUMO

Background: The success of pulpectomy depends on complete eradication of microbial load by cleaning and shaping the primary root canals that is difficult to achieve because of anatomical intricacy of primary pulp dentin complex. Numerous instruments were tried, however, they proved to be inadequate. Selfadjusting file (SAF) is a newer file system that facilitates less dentin removal with maximal cleansing of root canals. Aim: To evaluate and compare the in vitro root canal cleaning efficacy with SAF, Protaper Universal, and Hand K-files in primary teeth. Materials and Methods: Sixty extracted primary anterior teeth were randomly divided into three groups by lottery method. Access cavity was prepared, the canals were enlarged up to 20 K file, and an Indian ink was injected into each canal. Then the Group I (n = 20) was treated with SAF, Group II (n = 20) with Rotary Protaper Universal and Group III (n = 20) with Hand K-files and the root canal cleaning efficacy was evaluated based on the amount of Indian ink remaining in the canal walls under stereomicroscopy. Data were analyzed using Kruskal-Wallis one way ANOVA test and post hoc Tuckey test for intragroup and intergroup comparison, respectively. Results: A statistically highly significant difference was observed with SAF (mean = 1.5), Protaper (mean = 2.5), and Hand K-files (mean = 2.9). However, there was no significant difference in root canal cleaning efficacy with Protaper Universal and Hand K-files. Conclusion: The SAFs had shown superior cleaning efficacy compared with rotary Protaper Universal and manual K files.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Dente Decíduo , Cavidade Pulpar/microbiologia , Desenho de Equipamento , Tratamento do Canal Radicular , Dente Decíduo/microbiologia , Humanos
19.
Cureus ; 15(5): e38829, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37303406

RESUMO

AIM: This study set out to compare the damage done to dentin by three distinct titanium file brands - the Hyflex EDM, the ProTaper Next, and the Waveone Gold Nickel - in order to draw conclusions about which one is the most effective. MATERIALS AND METHODS: Forty-first premolars in the mandible with straight canals and single roots were instrumented using Hyflex EDM, Waveone Gold, and Protaper Next. Dentinal flaws after endodontic treatment were studied by sectioning specimens using a hard tissue microtome and analyzing them under a stereomicroscope. RESULTS: There was no discernible variation between the groups in the coronal third (p=0.312) or apical third (p=0.076). Hyflex EDM and Protaper Next differed significantly in the middle portion of the tape (p=0.016). The Hyflex EDM sample had the fewest cracks. There was no statistically significant difference between Hyflex EDM and Waveone Gold; however, Hyflex EDM had fewer fractures in the middle third of the sample than Waveone Gold did. CONCLUSION: Electric discharge machining (EDM) files made from Hyflex proved to be far superior to their Protaper Next and Waveone Gold counterparts as they induced the fewest cracks in the middle third of the root dentin.

20.
Children (Basel) ; 10(5)2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37238340

RESUMO

Traditional hand instrumentation is a commonly used technique to perform pulpectomy in deciduous teeth by most specialists in pedodontics. Lately, dentists have embraced rotary instrumentation as a safe and effective alternative. This study aimed to compare the efficacy of root canal preparation in extracted primary molars between manual and two rotary file systems using micro-CT. Thirty-six extracted human second primary mandibular molars were divided into three groups according to the instrumentation method: (1) Manually instrumented (MI) group (n = 9) in which the teeth were treated using K-files up to size 30; (2) Kedo-Ssystem (KS) group (n = 9); (3) ProTaper Gold system (PTG) group (n = 10) and control group (n-8). Each tooth was scanned before and after the retrograde root canal preparation. Residual dentin volume was calculated using micro-CT scans to evaluate the technique's efficacy. Additionally, the preparation time and procedural errors were recorded for each tooth preparation. A one-way ANOVA test was carried out to compare the groups' dentin volume and preparation time. The mean preparation time using the manual method (13.14 min) was more than two times longer than that of the rotary techniques (4.62 min and 6.45 min). The manual preparation method using a K-file removed almost half the root canal material when compared with the rotor method (p = 0.025). Conclusion: our results suggest that rotary instrumentation is more efficient for root canal preparation in primary teeth than the traditional manual method. This finding may call for a paradigm shift in current clinical practices, where manual instrumentation is still commonly preferred.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...